Home
Product
Solution
Cases
Media
Service
About
Contact
English
Power Quality Filters
For Motor Protection
EMC/RFI
AC/DC Reactors
Power Transformers
Load Bank
Regenerator and Brake Choppers
Power Resistors
High-Voltage Soft Starter
All Products
Passive Harmonic Filter
Harmonic Filters for Medium frequency furnace
Harmonic Filters for EC Fan
LCL Filters
Active Power Filter
Static Var Generator (SVG)
All Products
Sine Wave Filter
DV/DT filter
AC Output Reactor
All Products
3-Phase Neutral Line Filter
3-phase EMC/EMI Filters
DC Filters
Single-Phase EMC/EMI Filter
All Products
AC Line Reactor
AC Output Reactor
APF Filter Reactor
DC Built-in Reactor for Inverter
DC Filters for Rail Transit
DC Reactor
Detuned Reactor
Epoxy-resin filled Dry-type iron core series Reactor
Filtering Reactor for Regenerative drive & Photovoltaic
Load Reactor for load test simulator
Si-Fe Magnetic Core DC Reactor
All Products
Auto Transformer
Control Transformers
High-impedance Isolation transformer
Isolation transformer
Photovoltaic isolation transformer
Rectifier transformer
SC(B)Epoxy-resin filled Dry-type electric transformer
Three phase to single phase transformer
Transformer for Aerospace & Military
Waterproof transformers for ship
ZYSFG Phase-shifting rectifier transformer
All Products
AC Resistive Load Bank
AC Resistive-Inductive Load Bank
DC Load Bank
Inductive load bank
RCD Load bank
All Products
Dynamic Braking Unit High-end,heavy-load
Dynamic Braking Unit High-end,heavy-load, Medium voltage
Dynamic Braking Unit heavy-load
Dynamic Braking Unit ordinary light-load
Economic Energy Regenerator
Energy Regenerator for elevator
General Energy Regenerator
Special Energy Regenerator
All Products
Adjustable Resistor
Aluminum Housed Resistor
Aluminum Resistor Multi-Unit
Braking Resistor Box, Resistor cabinet
Golden Aluminum Housed resistor for led
RI82/RI80 Glass Enamel High-Voltage Resistor
Neutral Grounding Resistor
Stainless steel resistors
Vitreous enamel resistor
Wirewound Resistor
All Products
Can't find the product you need?
Harmonic Solution for VFD system & EC Fan
Harmonic Solution for Medium frequency furnace
Motor Protection solution
EMC/RFI Products
Solution for Load testing
Braking Solution for VFD System
Power Supply for Aerospace & Military
Solutions for Grid Connection
Transformer for Electroplating Field
Solution Overview
Solution Overview
Solution Overview
DV/DT Filter
Output Reactor
Sine Wave Filter
Solution Overview
Solution Overview
Solution Overview
Dynamic Braking
Regenerative Braking
Solution Overview
Solution Overview
Solution Overview
Can't find the product you need?
Client Visits
Company News
Company Video
Industry News
Product Video
Custom
Download
FAQ
Feedback
Certificate
Culture
History
Introduction
Principle
AC/DC Reactors
Choke,line reactor,DC choke,DC Reactor, AC choke,AC Reactor, input choke, input Reactor,output choke, output Reactor, APF Choke, APF Reactor, Detuned choke, Elevator Reactor, Elevator choke, Harmonic filter choke, Load Choke, DV/DT Reactor,
Home
›
Product
›
AC/DC Reactors
Back
Power Quality Filters
For Motor Protection
EMC/RFI
AC/DC Reactors
Power Transformers
Load Bank
Regenerator and Brake Choppers
Power Resistors
High-Voltage Soft Starter
AC Line Reactor
AC Output Reactor
APF Filter Reactor
DC Built-in Reactor for Inverter
DC Filters for Rail Transit
DC Reactor
Detuned Reactor
Epoxy-resin filled Dry-type iron core series Reactor
Filtering Reactor for Regenerative drive & Photovoltaic
Load Reactor for load test simulator
Si-Fe Magnetic Core DC Reactor
Sort By:
Default
By ID
Latest
Popular
Recommended
Load Reactor AC 3-Phase 400V ,1%(uK), Rated Current 1102A , 691KW
Model: SKS-HOCL-1102-4A5/0.32
Description of Load Reactor: SKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, re...
Filter Choke DROS Series 100A to 500A
Model: SKS-DROS-200A
This series chokes are designed for high-frequency inverter circuit and suitable for power supplier system of AC 10-30KHz frequency and below 1KV rated voltage, it is a string of high-frequency circuits in harmonic components which can protect other ...
Detuned Choke for reactive power compensation 30kva, 480V 7% drop
Model: SKS-DKR30-400V/P7-3
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 20kva, 480V 7% drop
Model: SKS-DKR20-400V/P7-3
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 7.49kvar, 400V 7% drop
Model: SKS-CKSGL-7.49-0.4
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 50kva, 480V 7% drop
Model: SKS-CKSGL-3.7/0.48-7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 2.1kva, 480V 7% drop
Model: SKS-CKSGL-2.1/0.48-7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 1.75kva, 480V 7% drop
Model: SKS-CKSGL-1.75/0.48-7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 60kvar, 575V 7% drop
Model: SKS-CKSGL-4.2/0.48-7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 4.07kvar, 575V 7% drop
Model: SKS-CKSGL-4.07/0.575-7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 40kva, 450V 7% drop
Model: SKS-CKSG-2.8-4A5/7
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Detuned Choke for reactive power compensation 121kva, 460V 13% drop
Model: SKS-CKSG-15.73-4A6/13
CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.
Choke Series-connection Epoxy-resin-filled Dry-type Iron-core CKSC-series
Model: SKS-CKSC-Series
Description of Series connection Choke: CKSC Series is suitable for power system of AC 50Hz rated operating voltage up to 6-38KV, with high voltage capacitor group in series. It can restrain from the high harmonic closing surge and operating overv...
Filtering Reactor, 500A ,0.2mH, for Regenerative drive,wind power, photovoltaic ,VFD and UPS
Model: SKS-AFER-0500-AB-6-0.2
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Filtering Reactor, 500A ,0.1mH, for Regenerative drive,wind power, photovoltaic ,VFD and UPS
Model: SKS-AFER-0500-AB-6-0.1
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Filtering Reactor for Regenerative drive,Rated Current 227A, 0.45mH
Model: SKS-AFER-0227-400
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Filtering Reactor for Regenerative drive,Rated Current 120A, 0.318mH
Model: SKS-AFER-0120-660
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Filtering Reactor ,Rated Current 33A, Rated voltage 27.5kV
Model: SKS-AFER-0033-A6/70KV
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Filtering Reactor for Regenerative drive,Rated Current 60A
Model: SKS-AFE-0060-AL/4-15.4
Description of filter reactor : Filter reactor together with capacitors can combine harmonic circuit to reduce the harmonic current in the system , mainly 3rd , 5th , 7th , 11th , 13th and higher . Filter reactor can be installed by parallel or seri...
Load Reactor dedicated for inverter testing 1500A,270Kva,15%
Model: SKS-FZ-1500-AB-4
Load reactor is designed to test frequency inverter.
1
2
Next →
Expert Support
Professional engineering services
Instant Response
Timely solutions
Customer First
Creating value continuously
Full Protection
Efficient logistics & after-sales
English
Deutsch
中文
Русский язык
Lingua italiana
Español
اَلْعَرَبِيَّةُ
Your Name
Your Email
*
NOTE: Entering the wrong email address will prevent you from receiving our reply!
Your Phone Number
Feedback Details
*
Verification Code
Select 1st-level category
Power Quality Filters
For Motor Protection
EMC/RFI
AC/DC Reactors
Power Transformers
Load Bank
Regenerator and Brake Choppers
Power Resistors
High-Voltage Soft Starter
Select 2nd-level category
Nominal Current Range
[ {label: '≤5A', value: 'le5A'}, {label: '5.1-50A', value: '5.1_50A'}, {label: '51-300A', value: '51_300A'}, {label: '301-800A', value: '301_800A'}, {label: '801-1600A', value: '801_1600A'}, {label: '>1600A', value: 'gt1600A'}, {label: 'Others', value: 'others'}, ]
Nominal Voltage Range
[ {label: '110-250V', value: '110V'}, {label: '251-440V', value: '251_440V'}, {label: '441-500V', value: '441_500V'}, {label: '501-690V', value: '501_690V'}, {label: '691-1140V', value: '691_1140V'}, {label: '1141-2000V', value: '1141_2000V'}, {label: 'Others', value: 'others'}, ]
System Voltage
[ {label: '110V', value: '110V'}, {label: '200-250V', value: '200_250V'}, {label: '380-440V', value: '380_440V'}, {label: '460-500V', value: '460_500V'}, {label: '600-690V', value: '600_690V'}, {label: '1140V', value: '1140V'}, {label: 'Others', value: 'others'}, ]
Power Range
[ {label: '<1KW', value: 'lt1KW'}, {label: '1.0-3.0KW', value: '1.0_3.0KW'}, {label: '3.01-6.0KW', value: '3.01_6.0KW'}, {label: '6.1-15KW', value: '6.1_15KW'}, {label: '15.1-110KW', value: '15.1_110KW'}, {label: '111-500KW', value: '111_500KW'}, {label: '501-1200KW', value: '501_1200KW'}, {label: '>1200KW', value: 'gt1200KW'}, {label: 'Others', value: 'others'}, ]
Operating Frequency
[ {label: '50Hz', value: '50Hz'}, {label: '60Hz', value: '60Hz'}, {label: '50/60Hz', value: '50or60Hz'}, {label: '0-120Hz', value: '0_120Hz'}, {label: '400Hz', value: '400Hz'}, {label: '1000Hz', value: '1000Hz'}, {label: 'Others', value: 'others'}, ]
Power system
[ {label: 'DC', value: 'DC'}, {label: 'Single-phase', value: '1phase'}, {label: 'Three-phase', value: '3phase'}, {label: 'Three-phase + Neutral', value: '3_n'}, {label: 'Others', value: 'others'}, ]
Reactance Rate
[ {label: '1%', value: '1'}, {label: '2%', value: '2'}, {label: '3%', value: '3'}, {label: '4%', value: '4'}, {label: '5%', value: '5'}, {label: '7%', value: '7'}, {label: '12%', value: '12'}, {label: '14%', value: '14'}, {label: 'Others', value: 'others'}, ]
IP Rating (Ingress Protection)
[ {label: 'IP00', value: 'IP00'}, {label: 'IP20', value: 'IP20'}, {label: 'IP21', value: 'IP21'}, {label: 'IP24', value: 'IP24'}, {label: 'IP54', value: 'IP54'}, {label: 'IP55', value: 'IP55'}, {label: 'IP56', value: 'IP56'}, {label: 'IP65', value: 'IP65'}, {label: 'Others', value: 'others'}, ]